S
IN
A
MICS
G1
30/G150
List
Manual (LH
2)
, 07/2
016
, A5E0326347
9A
11
3
5
3
F
un
ction dia
g
ra
ms
3.6
P
ROFIdr
ive
F
ig.
3
-29
24
27 – E_STW
1_BM control word, infeed
metal
industry
in
terconn
ecti
on
Function diagram
8
7
6
5
4
3
2
1
fp_2427_54_eng.vsd
DO: A_INF, B_INF, S_INF
S120/S150/G130/G150
27.06.13 V04.08.00
PROFIdrive - E_STW1_BM control word, infeed metal industry interconnection
Signal targets for E_STW1_BM
<1> Used in telegram 371.
<2> STW1.10 must be set to ensure that the drive object accepts the process data (PZD).
<3> Only for A_INF, S_INF.
<4> Only for A_INF.
<1>
STW1.0
p0840[0] = r2090.0
Signal
[Function diagram] signal target
[Function diagram] internal control word
Interconnection
parameters
STW1.1
p0844[0] = r2090.1
STW1.2
STW1.3
p0852[0] = r2090.3
STW1.4
-
STW1.5
p3532= r2090.5
STW1.6
p3533= r2090.6
STW1.7
p2103[0] = r2090.7
STW1.8
STW1.9
STW1.10
p0854[0] = r2090.10
STW1.11
STW1.12
STW1.13
STW1.14
STW1.15
[2546.3]
-
Inverted
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
[8060]
[8920.3]
[8920.3]
-
[8920.3]
-
[8920.3]
[8920.3]
-
-
[8920.3]
-
-
-
-
-
A_INF
[8720.3]
[8720.3]
-
-
-
-
-
[8720.3]
-
-
-
-
-
-
-
B_INF <7>
[8820.3]
[8820.3]
-
[8820.3]
-
[8820.3]
-
-
[8820.3]
-
-
-
-
-
-
S_INF <5>
[8932]
-
[8932]
-
-
-
-
-
-
-
-
[8932]
[8920]
[8920]
[8920]
A_INF
[8732]
-
-
-
-
[8720]
-
-
-
-
-
[8732]
-
-
-
B_INF <7>
[8832]
[8832]
-
[8832]
-
[8820]
-
-
[8820]
-
-
-
-
-
-
S_INF <5>
= ON
(close precharging/line contactor, pulses can be enabled)
0 = OFF1 (reduce Vdc along a ramp, suppress pulse and open precharging/line contactor)
Meaning
1 = No OFF2 (enable is possible)
0 = OFF2 (immediate pulse suppression and power-on inhibit)
Reserved
1 = Enable operation (pulses can be enabled)
0 = Inhibit operation (suppress pulses)
Reserved
1 = Infeed, inhibit motoring
1 = Infeed, inhibit regenerative operation
= Acknowledge faults
Reserved
Reserved
1 = Control by PLC
Reserved
Reserved
Reserved
Reserved
Controller-sign-of-life Toggle bit
<3>
<3>
<2>
<4>
- 2427 -
p2080[15] = r2090.15
<5> B_INF and S_INF only for S120.
<6> Interconnection is not disabled.
<7> Only for S120 and G150.
<8> Not for G130.
<6>
<6>
<6>
<6>
<6>
<6>
<6>
<6>
<6>
<6>
<6>
<6>
-
<7>
PROFIdrive sampling time
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......