2 Parameters
2.2 List of parameters
SINAMICS G130/G150
1068
List Manual (LH2), 07/2016, A5E03263479A
Description:
Sets the telegram for the safety information channel (SIC) / safety control channel (SCC).
The SIC/SCC telegram p60122 is attached directly to the PZD telegram p0922/p2079.
Value:
700:
Supplementary telegram 700, PZD-0/3
701:
Supplementary telegram 701, PZD-2/5
999:
Free telegram configuration with BICO
Note:
The clearance to the PZD telegram can be increased using p2070/p2071.
After changing p0922/p2079 or p2070/p2071, then p60122 must be set again.
The telegram interconnections can only be changed if p60122 and p0922 are both set to 999.
Description:
Displays PROFINET Name of Station.
Notice:
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
Description:
Displays PROFINET IP of Station.
p60122
IF1 PROFIdrive SIC/SCC telegram selection / IF1 SIC/SCC telegr
VECTOR_G
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
-
Func. diagram:
2423
P-Group:
Communications
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
700 999
999
r61000[0...239]
PROFINET Name of Station / PN Name of Station
CU_G130_PN,
CU_G150_PN,
CU_G130_DP (PN
CBE20),
CU_G150_DP (PN
CBE20)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
2410
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r61001[0...3]
PROFINET IP of Station / PN IP of Station
CU_G130_PN,
CU_G150_PN,
CU_G130_DP (PN
CBE20),
CU_G150_DP (PN
CBE20)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
2410
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......