2 Parameters
2.2 List of parameters
SINAMICS G130/G150
160
List Manual (LH2), 07/2016, A5E03263479A
Description:
Maximum angle when calculating the polynomial function to decouple the magnetic flux axes for permanent-magnet
synchronous motors (see p0398, p0399).
Description:
The magnetic cross coupling of the motor's d and q axes caused by saturation (current-dependent) leads to an angle
offset affecting the axis system d'q'; this decouples the magnetic quantities.
The angle offset can be described as a 3rd order polynomial function of the load current consumed:
phiOffset = f(C1*iq + C3*iq^3)
This parameter is the coefficient C1; it describes the linear load impact effect.
Description:
The magnetic cross coupling of the motor's d and q axes caused by saturation (current-dependent) leads to an angle
offset affecting the axis system d'q'; this decouples the magnetic quantities.
The angle offset can be described as a 3rd order polynomial function of the load current consumed:
phiOffset = f(C1*iq + C3*iq^3)
This parameter is the coefficient C3; it describes the cubic load impact effect.
Description:
Selects the encoder from the list of encoder types supported.
Value:
0:
No encoder
3001: 1024 HTL A/B R
3002: 1024 TTL A/B R
3003: 2048 HTL A/B R
3005: 1024 HTL A/B
3006: 1024 TTL A/B
3007: 2048 HTL A/B
p0397[0...n]
Angle magnetic decoupling maximum angle / Magn decpl max_ang
VECTOR_G
Can be changed:
U, T
Calculated:
CALC_MOD_EQU
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, SESM, REL,
RESM
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.0 [°]
90.0 [°]
90.0 [°]
p0398[0...n]
Angle magn decoupling (cross saturation) coeff 1 / Magn decoupl C1
VECTOR_G
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_EQU
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, SESM, REL,
RESM
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-10.000000 10.000000
0.000000
p0399[0...n]
Angle magn decoupling (cross saturation) coeff 3 / Magn decoupl C3
VECTOR_G
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_EQU
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, SESM, REL,
RESM
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-10.000000 10.000000
0.000000
p0400[0...n]
Encoder type selection / Enc_typ sel
VECTOR_G
Can be changed:
C2(1, 4)
Calculated:
-
Access level:
1
Data type:
Integer16
Dyn. index:
EDS, p0140
Func. diagram:
4700, 4704
P-Group:
Encoder
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 10000
0
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......