2 Parameters
2.2 List of parameters
SINAMICS G130/G150
724
List Manual (LH2), 07/2016, A5E03263479A
Description:
Sets the scaling for the integer number of the output signal for the function generator.
Dependency:
Refer to: r4805, r4817
Note:
The parameter can only be changed in the following operating states:
r4805 = 0, 4, 6
Description:
Display and connector output for the integer number of the output signal for the function generator.
Dependency:
Refer to: p4816
Note:
The value is output independent of the function generator operating mode.
Description:
Displays the output signal for the function generator.
Dependency:
Refer to: p4810
Note:
The value is displayed independently of the function generator mode.
Description:
Sets the signal source to control the function generator.
When the function generator is running, signal generation is stopped with a 0 signal from BI: p4819 and p4800 is set
to 0.
Dependency:
Refer to: p4800
p4816
Function generator output signal integer number scaling / FG outp integ scal
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Integer32
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-2147483648 2147483647
0
r4817
CO: Function generator output signal integer number / FG outp integ no.
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Integer32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
- -
-
r4818
CO: Function generator output signal / FG outp_sig
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
0
Min Max
Factory
setting
- [%]
- [%]
- [%]
p4819
BI: Function generator control / FG control
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
- -
1
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......