SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
291
2 Parameters
2.2 List of parameters
Caution:
Telegrams 2, 3 and 4 are not suitable for sensorless vector control (p1300 = 20). For sensorless vector control, it is
necessary that the setpoint speed is entered at the ramp-function generator input (e.g. p1070) and not after the
ramp-function generator (p1155).
Note:
If a value is not equal to 999, a telegram is set and the automatically set interconnections in the telegram are
inhibited. The inhibited interconnections can only be changed again after setting value 999.
Description:
Sets the send and receive telegram.
Value:
370:
SIEMENS telegram 370, PZD-1/1
371:
SIEMENS telegram 371, PZD-5/8
999:
Free telegram configuration with BICO
Note:
If a value is not equal to 999, a telegram is set and the automatically set interconnections in the telegram are
inhibited.
The inhibited interconnections can only be changed again after setting value 999.
Description:
Sets the send and receive telegram.
Value:
81:
SIEMENS telegram 81, PZD-2/6
82:
SIEMENS telegram 82, PZD-2/7
83:
SIEMENS telegram 83, PZD-2/8
999:
Free telegram configuration with BICO
Note:
If a value is not equal to 999, a telegram is set and the automatically set interconnections in the telegram are
inhibited.
The inhibited interconnections can only be changed again after setting value 999.
Description:
Displays the position of the "Pulses enabled" status signal in the PROFIdrive telegram.
Index:
[0] = Signal number
[1] = Bit position
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD telegr
B_INF
Can be changed:
C2(1), T
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
2401, 2420,
2423, 2447, 2457, 2481, 2483
P-Group:
Communications
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
370 999
999
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD telegr
ENC
Can be changed:
C2(1), T
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
2401, 2415,
2416, 2419, 2420, 2421, 2422,
2423
P-Group:
Communications
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
81 999
999
r0924[0...1]
ZSW bit pulses enabled / ZSW pulse enab
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
2454, 2456
P-Group:
Communications
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......