2 Parameters
2.2 List of parameters
For bit 05:
When know-how protection has been activated, the contents of the memory card (parameter and DCC data) can be
additionally protected against being used with other memory cards. This bit is only set if know-how protection is
active and p7765.1 is set = 1 and p7765.0 is set = 0.
For bit 06:
When know-how protection is activated, the drive data can be traced using the device trace function. This bit is only
set if know-how protection is active and p7765.2 is set = 1.
For bit 12:
Together with p7755, the bit is used to monitor write protection.
Bit = 1, if p7755 != 0 and write protection is active (p7760.0 = 1).
Bit = 0, if write protection was deactivated. p7755 is set to 0, and when write protection is activated again, bit 12
remains at 0.
Description:
Displays the status for the write protection and know-how protection.
Dependency:
Refer to: p7761, p7765, p7766, p7767, p7768
Note:
KHP: Know-How Protection
For bit 00:
Write protection can be activated/deactivated via p7761 on the Control Unit.
For bit 01:
The know-how protection can be activated by entering a password (p7766 ... p7768).
For bit 02:
If it has already been activated, know-how protection can be temporarily deactivated by entering the valid password
in p7766. In this case, bit 1 = 0 and bit 2 = 1 offset.
For bit 03:
Know-how protection cannot be deactivated, as p7766 is not entered in the OEM exception list (only the factory
setting is possible). This bit is only set if know-how protection is active (bit 1 = 1) and p7766 has not been entered in
the OEM exception list.
For bit 04:
When know-how protection has been activated, the contents of the memory card (parameter and DCC data) can be
additionally protected against being used with other memory cards/Control Units. This bit is only set if know-how
protection is active and in p7765.0 is set = 1.
For bit 05:
When know-how protection has been activated, the contents of the memory card (parameter and DCC data) can be
additionally protected against being used with other memory cards. This bit is only set if know-how protection is
active and p7765.1 is set = 1 and p7765.0 is set = 0.
For bit 06:
When know-how protection is activated, the drive data can be traced using the device trace function. This bit is only
set if know-how protection is active and p7765.2 is set = 1.
r7760
Write protection/know-how protection status / Wr_prot/KHP stat
VECTOR_G, B_INF,
TM31, TM120, TM150,
TB30, TM54F_MA,
TM54F_SL, ENC, HUB
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Write protection active
Yes
No
-
01
Know-how protection active
Yes
No
-
02
Know-how protection temporarily withdrawn Yes
No
-
03
Know-how protection cannot be deactivated Yes
No
-
04
Extended copy protection is active
Yes
No
-
05
Basic copy protection is active
Yes
No
-
06
Trace and measuring functions for
diagnostic purposes active
Yes
No
-
12
Reserved Siemens
Yes
No
-
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......