2 Parameters
2.2 List of parameters
SINAMICS G130/G150
760
List Manual (LH2), 07/2016, A5E03263479A
Description:
Displays the maximum rectifier temperature in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[2].
Description:
Displays the air intake temperature in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[3].
Description:
Displays the temperature of the electronics module in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[4].
Description:
Displays the inverter temperature 1 in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[5].
Description:
Displays the inverter temperature 2 in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[6].
r7203[0...n]
CO: Par_circuit power unit temperatures max. rectifier / PU temp max rect
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Unit group:
21_1
Unit selection:
p0505
Not for motor type:
-
Scaling:
p2006
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r7204[0...n]
CO: Par_circuit power unit temperatures air intake / PU temp air intake
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Unit group:
21_1
Unit selection:
p0505
Not for motor type:
-
Scaling:
p2006
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r7205[0...n]
Par_circuit power unit temperatures electronics / PU temp electr
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Unit group:
21_1
Unit selection:
p0505
Not for motor type:
-
Scaling:
p2006
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r7206[0...n]
Par_circuit power unit temperatures inverter 1 / PU temp inv 1
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Unit group:
21_1
Unit selection:
p0505
Not for motor type:
-
Scaling:
p2006
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r7207[0...n]
Par_circuit power unit temperatures inverter 2 / PU temp inv 2
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Unit group:
21_1
Unit selection:
p0505
Not for motor type:
-
Scaling:
p2006
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......