SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
639
2 Parameters
2.2 List of parameters
50:
Parameter download using commissioning software
90:
Reset Control Unit and delete drive objects
100:
Start initialization
101:
Wait for topology input
110:
Instantiate Control Unit basis
111:
Insert drive object
112:
Remove drive object
113:
Change drive object number
114:
Change component number
115:
Parameter download using commissioning software
117:
Remove component
150:
Wait until actual topology determined
160:
Evaluate topology
170:
Instantiate Control Unit reset
180:
Initialization YDB configuration information
200:
First commissioning
210:
Create drive packages
250:
Wait for topology acknowledge
325:
Wait for input of drive type
350:
Determine drive type
360:
Write into topology-dependent parameters
370:
Wait until p0009 = 0 is set
380:
Check topology
550:
Call conversion functions for parameter
625:
Wait non-cyclic starting DRIVE-CLiQ
650:
Start cyclic operation
660:
Evaluate drive commissioning status
670:
Autom. FW update DRIVE-CLiQ components
680:
Wait for CU LINK slaves
690:
Wait non-cyclic starting DRIVE-CLiQ
700:
Save parameters
725:
Wait until DRIVE-CLiQ cyclic
740:
Check the ability to operate
745:
Start of the time slices
750:
Interrupt enable
800:
Initialization finished
10050: Wait for synchronization
10100: Wait for CU LINK slaves
10150: Wait until actual topology determined
10200: Evaluate component status
10250: Call conversion functions for parameter
10300: Preparation cyclic operation
10350: Autom. FW update DRIVE-CLiQ components
10400: Wait for slave properties
10450: Check CX/NX status
10500: Wait until DRIVE-CLiQ cyclic
10550: Carry out warm start
10600: Evaluate, encoder status
10800: Partial boot completed
Index:
[0] = System
[1] = Partial boot
Description:
Displays whether writing to parameters is inhibited.
r3996[0] = 0:
Parameter write not inhibited.
r3996[0...1]
Parameter write inhibit status / Par_write inhib st
All objects
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......