SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
393
2 Parameters
2.2 List of parameters
Description:
Displays the sum of all speed setpoints that are present.
The following sources are available for the displayed setpoint:
- setpoint at the ramp-function generator input (r1119).
- speed setpoint 1 (p1155).
- speed setpoint 2 (p1160).
- speed setpoint for the speed pre-control (p1430).
- setpoint from DSC (for DSC active).
- setpoint via PC (for master control active).
Dependency:
Refer to: r1119, p1155, p1160
Description:
Display and connector output for the actual smoothed speed actual value of the speed control.
Description:
Sets the smoothing time for the speed actual value calculated by the motor model in sensorless operation.
Description:
Sets the smoothing time for the actual speed of the speed controller for encoderless closed-loop speed control.
Note:
The smoothing must be increased if there is gear backlash. For longer smoothing times, the integral time of the
speed controller must also be increased (e.g. using p0340 = 4).
r1444
Speed controller speed setpoint steady-state (static) / n_ctrl n_set stat
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
5030
P-Group:
Closed-loop control
Unit group:
3_1
Unit selection:
p0505
Not for motor type:
REL
Scaling:
p2000
Expert list:
1
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
r1445
CO: Actual speed smoothed / n_act smooth
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6040
P-Group:
Closed-loop control
Unit group:
3_1
Unit selection:
p0505
Not for motor type:
REL
Scaling:
p2000
Expert list:
1
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
p1451[0...n]
Motor model speed actual value smoothing time sensorless / Mot_mod n_act t_sm
VECTOR_G (n/M)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, PMSM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 [ms]
1000 [ms]
4 [ms]
p1452[0...n]
Speed controller speed actual value smoothing time (sensorless) / n_C n_act T_s SL
VECTOR_G (n/M)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6020, 6040
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [ms]
32000.00 [ms]
10.00 [ms]
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Page 1975: ......