657
CAN Controller (CAN)
Chapter 19
Preliminary User’s Manual U17566EE1V2UM00
Table 19-13
Types of error states
Note
If an error that increments the value of the transmission error counter by 8
while the counter value is in a range of 248 to 255, the counter is not
incremented and the bus-off state is assumed.
Type
Operation
Value of Error
Counter
Indication of
CnINFO Register
Operation Specific to Error State
Error active
Transmission
0 to 95
TECS1, TECS0 = 00
Outputs an active error flag (6 consecutive
dominant-level bits) on detection of the error.
Reception
0 to 95
RECS1, RECS0 = 00
Transmission
96 to 127
TECS1, TECS0 = 01
Reception
96 to 127
RECS1, RECS0 = 01
Error passive
Transmission
128 to 255
TECS1, TECS0 = 11
Outputs a passive error flag (6 consecutive
recessive-level bits) on detection of the error.
Transmits 8 recessive-level bits, in between
transmissions, following an intermission
(suspend transmission).
Reception
128 or more
RECS1, RECS0 = 11
Bus-off
Transmission
256 or more
(not
indicated)
Note
BOFF = 1,
TECS1, TECS0 = 11
Communication is not possible.
<1> TSOUT toggles.
<2> REC is incremented/decremented.
<3> VALID bit is set.
If the initialization mode is set and then 11
recessive-level bits are generated 128 times in
a row in an operation mode other than the
initialization mode, the error counter is reset to
0 and the error active state can be restored.