Baud rate setting example
Table 16-9
Baud rate generator setting data
Note
Table 16-9
assumes normal operation mode, i.e. PCLK1=8MHz.
16.6.6
Allowable baud rate range during reception
The baud rate error range at the destination that is allowable during reception
is shown below.
Caution
The baud rate error during reception must be set within the allowable error
range using the following equation.
Target
baud rate
UAnCTL1
UAnCTL2
Effective
baud rate
[bps]
Baud rate error
(%)
[bps]
Selector
Divider
Divider k
300
07H
128
68H
104
300.48
0.16
600
07H
128
34H
52
600.96
0.16
1,200
07H
128
1AH
26
1,201.92
0.16
2,400
07H
128
0DH
13
2,403.85
0.16
4,800
06H
64
0DH
13
4,807.69
0.16
9,600
05H
32
0DH
13
9,615.38
0.16
19,200
04H
16
0DH
13
19,230.77
0.16
31,250
05H
32
04H
4
31,250.00
0.00
38,400
03H
8
0DH
13
38,461.54
0.16
76,800
02H
4
0DH
13
76,923.08
0.16
153,600
01H
2
0DH
13
153,846.15
0.16
312,500
00H
1
0DH
13
307,692.31
–1.54