background image

GSM gate controller GV17

 

 

Short installation manual 

You can use GV17 controller to remotely control gates, barriers and 
other equipment.  

Control the system with Protegus app, phone call or SMS. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation and wiring 

 

Remove the upper cover, pull out 
the terminal block connector. 

 

 

 

Take out the PCB board from 
the casing. Fix the casing to 
chosen place with self-tapping 
screws.  

 

Place the PCB board back into the casing. Insert the terminal block. 

 

Screw the GSM antenna to the antenna connector.  

 

Place a Nano size SIM card to the SIM card slot.  

 

 

 

!!  It  is  necessary  to  disable  the  SIM  card  PIN  code  request  before 
inserting the SIM to GV17! You can do this using a mobile phone. 

Alternatively,  you  can  enter  the  SIM  card  PIN  via  TrikdisConfig

 

program using a USB. 

 

This manual describes how to install GV17 without configuring it via USB. 

If needed, using TrikdisConfig program or Protegus application you can: 

-

 

Add and delete users (up to 990) and administrators (up to 7). 

-

 

Check the events log. 

Additionally, using TrikdisConfig program you can: 

-

 

Set a schedule when users can control the system; 

-

 

Set  a counter for how many times certain users can control the 
system; 

-

 

Customize what SMS text will be sent after an input or output 
is activated or restored. 

-

 

Set dual purpose contacts to operate in input or output mode; 

-

 

Set input type (NC, NO, EOL) and output type (pulse, level); 

-

 

Turn on event reporting to security company receiver; 

-

 

Etc. 

Find the configuration program TrikdisConfig and product specifications 
i

GV17 page on trikdis.com

 

Summary of Contents for GV17

Page 1: ...a mobile phone Alternatively you can enter the SIM card PIN via TrikdisConfig program using a USB This manual describes how to install GV17 without configuring it via USB If needed using TrikdisConfig program or Protegus application you can Add and delete users up to 990 and administrators up to 7 Check the events log Additionally using TrikdisConfig program you can Set a schedule when users can c...

Page 2: ...l Usually these contacts are a certain input x IN and common terminal COM The automatic gate has a gate state output OUT that shows when the gates are closed and when they are open The gate s state output can be a voltage output or a relay output In the schematic relay K1 is connected to a voltage automated gate output There is voltage 230V between the voltage outputs OUT and N of the automated ga...

Page 3: ...0 to 5 Sufficient is 3 DATA Green solid Sending message Yellow solid Unsent events are stored in buffer POWER Blinking green Power supply is sufficient Blinking yellow Low power supply voltage Blinking green and yellow Configuration mode TROUBLE Not solid and not blinking No trouble 1 blink No SIM card 2 blinks Incorrect SIM card PIN code 3 blinks Cannot connect to GSM network 4 blinks Cannot conn...

Page 4: ...egus system window click the button Control Click the control button Shining light or opened gates show that GV17 controllable output is active Remote control via SMS Control the relay output 5 OUT with these SMS commands OUTPUT5 xxxxxx ON OUTPUT5 xxxxxx OFF OUTPUT5 xxxxxx PULSE 002 xxxxxx 6 digit administrator password ON Turn on the output OFF Turn off the output PULSE ttt Turn on the output for...

Page 5: ...A xxxxxx NoX PHONENo NAME xxxxxx 6 digit administrator password NoX X administrator s number in the list PHONENo User s phone number NAME User s name or email address The list of SMS commands Command Data Description INFO Request information about the controller The response will include controller type IMEI number serial number and software version E g INFO 123456 OUTPUTx ON Turn on the output x ...

Page 6: ...ountry code E g SETU 123456 37061234567 John Snow DELU PhoneNo Delete a user using his phone number E g DELU 123456 37061234567 Name Delete a user using his name E g DELU 123456 John Snow SETD IDx yy Set x input inactivity time yy is the inactivity time in minutes from 0 to 2880 After the input is activated controller will send a notification and will not react to following circuit disruptions dur...

Page 7: ...nfig from www trikdis com Make sure that the controller is connected to the internet and the communication with Protegus is enabled see part III Remote control via Protegus application After opening the program enter the IMEI Unique ID number of the device to Unique ID field and click Configure Click Read F4 to read the parameters already set in the controller Set the needed settings and after the...

Reviews: