:MARKer Commands
20
Keysight InfiniiVision M9241/42/43A PXIe Oscilloscopes SCPI Programmer's Guide
427
:MARKer:X1Position
Command Syntax
:MARKer:X1Position <position> [suffix]
<position> ::= X1 cursor position in NR3 format
<suffix> ::= {s | ms | us | ns | ps | Hz | kHz | MHz}
The :MARKer:X1Position command:
• Sets :MARKer:MODE to MANual if it is not currently set to WAVeform (see
• Sets the X1 cursor position to the specified value.
X cursor units are set by the :MARKer:XUNits command.
Query Syntax
:MARKer:X1Position?
The :MARKer:X1Position? query returns the current X1 cursor position. This is
functionally equivalent to the obsolete :MEASure:TSTArt command/query.
Return Format
<position><NL>
<position> ::= X1 cursor position in NR3 format
See Also
•
"Introduction to :MARKer Commands"
•
•
•
•
•
•
NOTE
If the front-panel cursors are off, the marker position values are not defined and an error is
generated. Make sure to set :MARKer:MODE to MANual or WAVeform to put the cursors in the
front-panel Normal mode.