:SBUS<n>:A429:SPEed
Command Syntax
:SBUS<n>:A429:SPEed <speed>
<speed> ::= {LOW | HIGH | USER}
The :SBUS<n>:A429:SPEed command specifies the signal speed:
• LOW — 12.5 kb/s.
• HIGH — 100 kb/s.
• USER — lets you specify a user-defined baud rate using the
:SBUS<n>:A429:BAUDrate command.
Query Syntax
:SBUS<n>:A429:SPEed?
The :SBUS<n>:A429:SPEed? query returns the current ARINC 429 signal speed
setting.
Return Format
<speed><NL>
<speed> ::= {LOW | HIGH | USER}
Errors
•
See Also
•
•