1086
Keysight InfiniiVision M9241/42/43A PXIe Oscilloscopes SCPI Programmer's Guide
31
:TRIGger Commands
:TRIGger:EBURst Commands
The :TRIGger:EBURst:SOURce command is used to specify the source channel for
the Nth Edge Burst trigger. If an analog channel is selected as the source, the
:TRIGger:EDGE:LEVel command is used to set the Nth Edge Burst trigger level.
Table 131
:TRIGger:EBURst Commands Summary
Command
Query
Options and Query Returns
:TRIGger:EBURst:COUNt
<count> (see
)
:TRIGger:EBURst:COUNt
<count> ::= integer in NR1 format
:TRIGger:EBURst:IDLE
<time_value> (see
)
:TRIGger:EBURst:IDLE?
<time_value> ::= time in seconds
in NR3 format
:TRIGger:EBURst:SLOPe
<slope> (see
)
:TRIGger:EBURst:SLOPe
<slope> ::= {NEGative | POSitive}
:TRIGger:EBURst:SOURc
e <source> (see
)
:TRIGger:EBURst:SOURc
<source> ::= CHANnel<n>
<n> ::= 1 to (# analog channels)
in NR1 format