:CHANnel<n> Commands
10
Keysight InfiniiVision M9241/42/43A PXIe Oscilloscopes SCPI Programmer's Guide
293
:CHANnel<n>:PROBe:HEAD[:TYPE]
Command Syntax
:CHANnel<n>:PROBe:HEAD[:TYPE] <head_param>
<head_param> ::= {SEND0 | SEND6 | SEND12 | SEND20 | DIFF0 | DIFF6
| DIFF12 | DIFF20 | DSMA | DSMA6 | NONE}
<n> ::= {1 | 2 | 3 | 4}
The :CHANnel<n>:PROBe:HEAD[:TYPE] command sets an analog channel probe
head type and dB value. You can choose from:
• SEND0 — Single-ended, 0 dB.
• SEND6 — Single-ended, 6 dB.
• SEND12 — Single-ended, 12 dB.
• SEND20 — Single-ended, 20 dB.
• DIFF0 — Differential, 0 dB.
• DIFF6 — Differential, 6 dB.
• DIFF12 — Differential, 12 dB.
• DIFF20 — Differential, 20 dB.
• DSMA — Differential SMA probe head, 0 dB.
• DSMA6 — Differential SMA probe head, 6 dB.
Query Syntax
:CHANnel<n>:PROBe:HEAD[:TYPE]?
The :CHANnel<n>:PROBe:HEAD[:TYPE]? query returns the current probe head
type setting for the selected channel.
Return Format
<head_param><NL>
<head_param> ::= {SEND0 | SEND6 | SEND12 | SEND20 | DIFF0 | DIFF6
| DIFF12 | DIFF20 | DSMA | DSMA6 | NONE}
See Also
•
"Introduction to :CHANnel<n> Commands"
•
•
•
•
NOTE
This command is valid only for the 113xA Series probes.