1220
Keysight InfiniiVision M9241/42/43A PXIe Oscilloscopes SCPI Programmer's Guide
33
:WGEN<w> Commands
:WGEN<w>:FUNCtion
Command Syntax
:WGEN<w>:FUNCtion <signal>
<w> ::= 1 to (# WaveGen outputs) in NR1 format
<signal> ::= {SINusoid | SQUare | RAMP | PULSe | DC | NOISe | SINC
| EXPRise | EXPFall | CARDiac | GAUSsian | ARBitrary}
The :WGEN<w>:FUNCtion command selects the type of waveform:
Waveform
Type
Characteristics
Frequency
Range
Max.
Amplitude
2
(High-Z)
1
Offset
2
(High-Z)
1
SINusoid
Use these commands to set the sine signal
parameters:
•
•
•
•
•
•
100 mHz to
20 MHz
20 mVpp to
10 Vpp
±4.00 V
SQUare
Use these commands to set the square wave signal
parameters:
•
•
•
•
•
•
•
":WGEN<w>:FUNCtion:SQUare:DCYCle"
The duty cycle can be adjusted from 20% to 80%.
100 mHz to
10 MHz
20 mVpp to
10 Vpp
±5.00 V