822
Keysight InfiniiVision M9241/42/43A PXIe Oscilloscopes SCPI Programmer's Guide
27
:SBUS<n> Commands
:SBUS<n>:LIN:SYNCbreak
Command Syntax
:SBUS<n>:LIN:SYNCbreak <value>
<value> ::= integer = {11 | 12 | 13}
The :SBUS<n>:LIN:SYNCbreak command sets the length of the LIN sync break to
be greater than or equal to 11, 12, or 13 clock lengths. The sync break is the idle
period in the bus activity at the beginning of each packet that distinguishes one
information packet from the previous one.
Query Syntax
:SBUS<n>:LIN:SYNCbreak?
The :SBUS<n>:LIN:SYNCbreak? query returns the current LIN sync break setting.
Return Format
<value><NL>
<value> ::= {11 | 12 | 13}
See Also
•
"Introduction to :TRIGger Commands"
•
•
":SBUS<n>:LIN:SIGNal:DEFinition"
•