Table 4.6 AC Reactors (ACRs) External Dimensions
Dimensions (mm)
Power
supply
voltage
Nominal
applied
motor
(kW)
Inverter type
AC reactor
type
Fig.
W
W1
D
D1
D2
Mounting
hole G
H
Terminal
hole J
Approx.
mass
(kg)
0.75 FRN0.75AQ1
-4
ACR4-0.75A
120
40
90
65
90
M5 (6×10) 85
M4
1.1
1.5 FRN1.5AQ1
-4
ACR4-1.5A
125
40
100
75
90
M5
(6×10) 85 M4
1.9
2.2 FRN2.2AQ1
-4
ACR4-2.2A
125
40
100
75
90
M5
(6×10) 95 M4
2.2
3.7
(4.0) *
FRN3.7AQ1
-4
FRN4.0AQ1
-4E
ACR4-3.7A
125
40
115
90
90
M5 (6×10)
95
M4
2.4
5.5 FRN5.5AQ1
-4
ACR4-5.5A
A
125
40
115
90
90
M5 (6×10)
95
M5
3.1
7.5 FRN7.5AQ1
-4
ACR4-7.5A
125
40
115
90
90
M5
(6×10) 95 M5
3.7
11 FRN11AQ1
-4
ACR4-11A
180
60
100
85
90
M6
(7×11) 115 M6 4.3
15 FRN15AQ1
-4
ACR4-15A
180
60
110
85
90
M6
(7×11) 137 M6 5.4
18.5 FRN18.5AQ1
-4
ACR4-18.5A
180
60
110
85
90
M6 (7×11) 137 M6
5.7
22 FRN22AQ1
-4
ACR4-22A
180
60
110
85
90
M6
(7×11) 137 M6 5.9
30 FRN30AQ1
-4
37 FRN37AQ1
-4
ACR4-37
B
190
60
120
90
172
M6 (7×11) 190
M8
12
45 FRN45AQ1
-4
55 FRN55AQ1
-4
ACR4-55 190
60
120
90
200
M6
(7×11)
190 M10 14
75 FRN75AQ1
-4
ACR4-75
190
60
126
90
157
M6
(7×10) 190 M10 16
90 FRN90AQ1
-4
110 FRN110AQ1S-4
ACR4-110 250 100 136 105 202 M8
(9.5×18)
245
M12
24
132 FRN132AQ1S-4
ACR4-132
250 100 146 115 207 M8
(10×16) 250 M12
32
160 FRN160AQ1S-4
200 FRN200AQ1S-4
220 FRN220AQ1S-4
ACR4-220 320 120 150 110 240 M10
(12×20)
300
M12
40
280 FRN280AQ1S-4
ACR4-280
C
380 130 150 110 260 M10 (12×20) 300
M12
52
315 FRN315AQ1S-4
355 FRN355AQ1S-4
ACR4-355 380 130 150 110 260 M10
(12×20)
300
M12
52
400 FRN400AQ1S-4
ACR4-450
D
460 155 290 230 200
M12 (
φ
15) 490 4×M12 95
500 FRN500AQ1S-4
ACR4-530
480 155 420 370
- M12
(15×25) 380 4×M12 100
630 FRN630AQ1S-4
ACR4-630
E
510 170 420 370
- M12
(15×25)
390 4×M12 110
Three-
phase
400 V
710 FRN710AQ1S-4
Not
available
* 4.0 kW for the EU. The inverter type is FRN4.0AQ1
-4E.
Note:
A box (
) replaces an alphabetic letter depending on the enclosure.
M (IP21) or L (IP55)
A box (
) replaces an alphabetic letter depending on the shipping destination.
E (EU), A (Asia), or C (China)
Summary of Contents for FRENIC-AQUA series
Page 1: ...MEHT538b...
Page 2: ...User s Manual...
Page 13: ......
Page 15: ......
Page 33: ......
Page 35: ......
Page 61: ...2 26 Figure D Figure E NC No connection Do not make wiring NC NC...
Page 63: ...2 28 Figure J Figure K Charging lamp Charging lamp Viewed from A...
Page 83: ...2 48 Unit mm FRN45 to 55AQ1 4...
Page 84: ...2 9 External Dimensions 2 49 Chap 2 SPECIFICATIONS Unit mm FRN75 to 90AQ1 4...
Page 85: ...2 50 Unit mm FRN110AQ1S 4 FRN132AQ1S 4 FRN160AQ1S 4 FRN200AQ1S 4...
Page 87: ...2 52 Unit mm FRN500AQ1S 4 FRN630AQ1S 4 FRN710AQ1S 4...
Page 88: ...2 9 External Dimensions 2 53 Chap 2 SPECIFICATIONS 2 9 2 Keypad Unit mm Panel cutout...
Page 95: ......
Page 140: ...4 4 Options 4 33 Chap 4 SELECTING PERIPHERAL EQUIPMENT...
Page 279: ......
Page 281: ......
Page 341: ...6 60 Example of Thermal Overload Detection Characteristics...
Page 637: ......
Page 639: ......
Page 651: ...7 12 Figure 7 7 Terminal FM2 Output Selector...
Page 653: ......
Page 663: ......
Page 665: ......
Page 699: ......
Page 717: ......
Page 719: ......
Page 733: ......
Page 749: ......
Page 751: ...MEHT537 Phone 81 3 5435 7058 Fax 81 3 5435 7420 Printed in Japan 2012 08 H12b b12 CM00FOLS...