4.4 Options
4-45
Chap. 4
SEL
ECT
ING PE
RIPH
ER
AL
EQUI
PME
N
T
4.4.3
Selecting Option Cards
4.4.3.1
List of option cards, connection ports, and applicable ROM versions
The table below lists the option cards, option connection ports, and applicable ROM versions.
(Function enhancement or version update in the future may provide new options. For options not listed
below, contact Fuji Electric or visit our website.)
Option connection ports
Option type
Model name
A-port B-port C-port
ROM version
Remarks
OPC-RY
√
√
--
1000 or later Two option cards connectable at a
time to A- and B-ports (4 outputs).
Relay output
OPC-RY2 --
√
√
1000 or later A single option card connectable to B-
and C-ports (both ports occupied)
OPC-AIO
√
√
√
1300 or later A single option card connectable at a
time to any one of A-, B- and C-ports.
OPC-AO
√
√
√
1000 or later A single option card connectable at a
time to any one of A-, B- and C-ports.
I/O
OPC-PT
√
√
√
1300 or later A single option card connectable at a
time to any one of A-, B- and C-ports.
OPC-DEV
√
√
√
1000 or later
OPC-COP
√
--
--
1000 or later
OPC-PDP2
√
--
--
1000 or later
OPC-CCL
√
--
--
1000 or later
OPC-LNW
√
--
--
1000 or later
Communication
OPC-ETH
√
--
--
1000 or later
Only one of these communications
option cards connectable to the
inverter at a time. (e.g. Connection of
both OPC-DEV and OPC-CCL at a
time is not possible.)
• Two relay output interface cards OPC-RY can be
mounted concurrently.
• The analog interface card OPC-AIO and analog current
output interface card OPC-AO cannot be mounted
concurrently.
C-port
B-port
A-port
Control circuit
terminal block
CN6
CN5
CN4
Summary of Contents for FRENIC-AQUA series
Page 1: ...MEHT538b...
Page 2: ...User s Manual...
Page 13: ......
Page 15: ......
Page 33: ......
Page 35: ......
Page 61: ...2 26 Figure D Figure E NC No connection Do not make wiring NC NC...
Page 63: ...2 28 Figure J Figure K Charging lamp Charging lamp Viewed from A...
Page 83: ...2 48 Unit mm FRN45 to 55AQ1 4...
Page 84: ...2 9 External Dimensions 2 49 Chap 2 SPECIFICATIONS Unit mm FRN75 to 90AQ1 4...
Page 85: ...2 50 Unit mm FRN110AQ1S 4 FRN132AQ1S 4 FRN160AQ1S 4 FRN200AQ1S 4...
Page 87: ...2 52 Unit mm FRN500AQ1S 4 FRN630AQ1S 4 FRN710AQ1S 4...
Page 88: ...2 9 External Dimensions 2 53 Chap 2 SPECIFICATIONS 2 9 2 Keypad Unit mm Panel cutout...
Page 95: ......
Page 140: ...4 4 Options 4 33 Chap 4 SELECTING PERIPHERAL EQUIPMENT...
Page 279: ......
Page 281: ......
Page 341: ...6 60 Example of Thermal Overload Detection Characteristics...
Page 637: ......
Page 639: ......
Page 651: ...7 12 Figure 7 7 Terminal FM2 Output Selector...
Page 653: ......
Page 663: ......
Page 665: ......
Page 699: ......
Page 717: ......
Page 719: ......
Page 733: ......
Page 749: ......
Page 751: ...MEHT537 Phone 81 3 5435 7058 Fax 81 3 5435 7420 Printed in Japan 2012 08 H12b b12 CM00FOLS...