6-274
J461
Motor Increase/Decrease Switching Judgment Non-responsive Area Width
■
Motor increase/decrease switching judgment non-responsive area width (J461)
In the PID control, no motor increase/decrease judgment will be performed as long as the
deviation between the PID command value (SV value) and the PID feedback value is less
than the specified value.
- Data setting range: OFF, 0.1 to 50.0%
Data for J461
Description
0.1 to 50.0% Deviation between PID command value (SV value) and PID feedback value,
assuming 100% of PID feedback full scale.
OFF
Disable (Always perform motor increase/decrease judgment)
J462
Failure Inverter Judgment Time
In the communications-linked inverter drive motor floating system (J401 = 52), if PID control
comes to be at the hold state in the inverter running under PID control due to the limiter (e.g.,
current limit), then it is judged whether to exclude the PID control inverter.
If any other ready-to-run inverter exists in the system and the failure inverter judgment time
(J462) has elapsed, the current PID control inverter will be switched to the other one.
This switching does not involve increase/decrease of inverters or regular switching even if
their conditions are met.
If J462 = OFF, no switching occurs. During auto search for idling motor speed, no PID
control inverter will be switched even if PID control comes to be at the hold state.
- Data setting range: OFF, 0.5 to 600.0 s
Summary of Contents for FRENIC-AQUA series
Page 1: ...MEHT538b...
Page 2: ...User s Manual...
Page 13: ......
Page 15: ......
Page 33: ......
Page 35: ......
Page 61: ...2 26 Figure D Figure E NC No connection Do not make wiring NC NC...
Page 63: ...2 28 Figure J Figure K Charging lamp Charging lamp Viewed from A...
Page 83: ...2 48 Unit mm FRN45 to 55AQ1 4...
Page 84: ...2 9 External Dimensions 2 49 Chap 2 SPECIFICATIONS Unit mm FRN75 to 90AQ1 4...
Page 85: ...2 50 Unit mm FRN110AQ1S 4 FRN132AQ1S 4 FRN160AQ1S 4 FRN200AQ1S 4...
Page 87: ...2 52 Unit mm FRN500AQ1S 4 FRN630AQ1S 4 FRN710AQ1S 4...
Page 88: ...2 9 External Dimensions 2 53 Chap 2 SPECIFICATIONS 2 9 2 Keypad Unit mm Panel cutout...
Page 95: ......
Page 140: ...4 4 Options 4 33 Chap 4 SELECTING PERIPHERAL EQUIPMENT...
Page 279: ......
Page 281: ......
Page 341: ...6 60 Example of Thermal Overload Detection Characteristics...
Page 637: ......
Page 639: ......
Page 651: ...7 12 Figure 7 7 Terminal FM2 Output Selector...
Page 653: ......
Page 663: ......
Page 665: ......
Page 699: ......
Page 717: ......
Page 719: ......
Page 733: ......
Page 749: ......
Page 751: ...MEHT537 Phone 81 3 5435 7058 Fax 81 3 5435 7420 Printed in Japan 2012 08 H12b b12 CM00FOLS...