6-6
Code Name
Data
setting
range
Change
when
running
Data
copying
Default
setting
190 (1190): Cancel timer
(
TMC
)
191 (1191): Enable timer 1
(
TM1
)
192 (1192): Enable timer 2
(
TM2
)
193 (1193): Enable timer 3
(
TM3
)
194 (1194): Enable timer 4
(
TM4
)
201 (1201): External PID control 1 ON command (
EPID1-ON
)
202 (1202): Cancel external PID control 1
(
%/EPID1
)
203 (1203): Switch normal/inverse operation
under external PID control 1
(
EPID1-IVS
)
204 (1204): Reset external PID1 integral and
differential components
(
EPID1-RST
)
205 (1205): Hold external PID1 integral component
(
EPID1-HLD
)
211 (1211): External PID control 2 ON command (
EPID2-ON
)
212 (1212): Cancel external PID control 2
(
%/EPID2
)
213 (1213): Switch normal/inverse operation
under external PID control 2
(
EPID2-IVS
)
214 (1214): Reset external PID2 integral and
differential components
(
EPID2-RST
)
215 (1215): Hold external PID2 integral component
(
EPID2-HLD
)
221 (1221): External PID control 3 ON command (
EPID3-ON
)
222 (1222): Cancel external PID control 3
(
%/EPID3
)
223 (1223): Switch normal/inverse operation
under external PID control 3
(
EPID3-IVS
)
224 (1224): Reset external PID3 integral and
differential components
(
EPID3-RST
)
225 (1225): Hold external PID3 integral component
(
EPID3-HLD
)
Setting the value in parentheses ( ) shown above assigns a
negative logic output to a terminal. (True if OFF.)
Setting the value of 1000s in parentheses ( ) shown above
assigns a negative logic input to a terminal.
E10 Acceleration
Time
2
Y Y
20.00
E11 Deceleration
Time
2
Y Y
20.00
E12 Acceleration
Time
3
Y Y
20.00
E13 Deceleration
Time
3
Y Y
20.00
E14 Acceleration
Time
4
Y Y
20.00
E15 Deceleration
Time
4
0.00 to 3600.00 s
Note: Entering 0.00 cancels the acceleration time, requiring
external soft-start and -stop.
Y Y
20.00
E16 Torque
Limiter
2
(Driving)
Y Y
OFF
E17
(Braking)
OFF: Disable
20% to 150%: Torque limiter level
Y Y
OFF
E20 Terminal [Y1] Function
N Y 0
E21 Terminal [Y2] Function
N Y 1
E22 Terminal [Y3] Function
N Y 2
E23 Terminal [Y4] Function
N Y 7
E24 Terminal [Y5A/C] Function
N Y 15
E27 Terminal [30A/B/C] Function
(Relay
output)
Selecting function code data assigns the corresponding function
to terminals [Y1] to [Y5A/C] and [30A/B/C] as listed below.
0 (1000):
Inverter running
(
RUN
)
1 (1001):
Frequency (speed) arrival signal
(
FAR
)
2 (1002):
Frequency (speed) detected
(
FDT
)
3 (1003):
Undervoltage detected (Inverter stopped)
(
LV
)
5 (1005):
Inverter output limiting
(
IOL
)
6 (1006):
Auto-restarting after momentary power
failure (
IPF
)
7 (1007):
Motor overload early warning
(
OL
)
10 (1010): Inverter ready to run
(
RDY
)
11:
Switch motor drive source between
commercial power and inverter output
(For MC on commercial line)
(
SW88
)
12:
Switch motor drive source between
commercial power and inverter output
(For secondary side)
(
SW52-2
)
13:
Switch motor drive source between
commercial power and inverter output
(For primary side)
(
SW52-1
)
15 (1015): Select
AX
terminal function
(For MC on primary side)
(
AX
)
16 (1016): Shifted to pattern operation stage
(
TU
)
17 (1017): Pattern operation cycle completed
(
TO
)
18 (1018): Pattern operation stage number
(
STG1
)
19 (1019): Pattern operation stage number
(
STG2
)
20 (1020): Pattern operation stage number
(
STG4
)
22 (1022): Inverter output limiting with delay
(
IOL2
)
25 (1025): Cooling fan in operation
(
FAN
)
26 (1026): Auto-resetting
(
TRY
)
27 (1027): Universal DO
(
U-DO
)
28 (1028): Heat sink overheat early warning
(
OH
)
30 (1030): Lifetime alarm
(
LIFE
)
31 (1031): Frequency (speed) detected 2
(
FDT2
)
33 (1033): Reference loss detected
(
REF OFF
)
35 (1035): Inverter output on
(
RUN2
)
36 (1036): Overload prevention control
(
OLP
)
37 (1037): Current detected
(
ID
)
42 (1042): PID alarm
(
PID-ALM
)
43 (1043): Under PID control
(
PID-CTL
)
N Y 99
Summary of Contents for FRENIC-AQUA series
Page 1: ...MEHT538b...
Page 2: ...User s Manual...
Page 13: ......
Page 15: ......
Page 33: ......
Page 35: ......
Page 61: ...2 26 Figure D Figure E NC No connection Do not make wiring NC NC...
Page 63: ...2 28 Figure J Figure K Charging lamp Charging lamp Viewed from A...
Page 83: ...2 48 Unit mm FRN45 to 55AQ1 4...
Page 84: ...2 9 External Dimensions 2 49 Chap 2 SPECIFICATIONS Unit mm FRN75 to 90AQ1 4...
Page 85: ...2 50 Unit mm FRN110AQ1S 4 FRN132AQ1S 4 FRN160AQ1S 4 FRN200AQ1S 4...
Page 87: ...2 52 Unit mm FRN500AQ1S 4 FRN630AQ1S 4 FRN710AQ1S 4...
Page 88: ...2 9 External Dimensions 2 53 Chap 2 SPECIFICATIONS 2 9 2 Keypad Unit mm Panel cutout...
Page 95: ......
Page 140: ...4 4 Options 4 33 Chap 4 SELECTING PERIPHERAL EQUIPMENT...
Page 279: ......
Page 281: ......
Page 341: ...6 60 Example of Thermal Overload Detection Characteristics...
Page 637: ......
Page 639: ......
Page 651: ...7 12 Figure 7 7 Terminal FM2 Output Selector...
Page 653: ......
Page 663: ......
Page 665: ......
Page 699: ......
Page 717: ......
Page 719: ......
Page 733: ......
Page 749: ......
Page 751: ...MEHT537 Phone 81 3 5435 7058 Fax 81 3 5435 7420 Printed in Japan 2012 08 H12b b12 CM00FOLS...