2-8
Item
Explanation
Remarks
Fuse blown
Detects a break of the main circuit fuse in the inverter and stops the inverter. (For inverters
of 110 kW or above)
FUS
Charger circuit error
Detects a charger circuit error and stops the inverter. (For inverters of 45 kW or above)
PbF
Electronic thermal
overload protection
Stops the inverter with the electronic thermal overload protection setting to protect the
motor.
Protects general-purpose motors and inverter motors over all frequency range. (It is
possible to set the running level and thermal time constant (0.5 to 75.0 min).)
OL1
PTC thermistor
Detects the motor temperature to stop the inverter for protecting the motor.
Connect a PTC thermistor between terminals [C1] and [11] and configure the switch on the
control printed circuit board and function codes.
OH4
Motor protection
Overload early
warning
The inverter outputs a warning signal at the predetermined level before stop.
-
Memory error
The inverter checks memory data when the power is turned ON or data is written. If any
memory error is detected, the inverter stops.
Er1
Keypad
communications error
The error detection function stops the inverter output upon detection of a communications
error between the keypad and the inverter control circuit during operation using the keypad.
Er2
CPU error
If the inverter detects a CPU error or LSI error caused by noise or some other factors, this
function stops the inverter output.
Er3
Option
communications error
Upon detection of an error in communication between the inverter and an option card, this
function stops the inverter output.
Er4
Option error
When an option card detects an error, this function stops the inverter output.
Er5
STOP key priority: Pressing the
key on the keypad forcibly decelerates the motor to a
stop even when a run command is given via the terminal block or communications link.
After the stop, the inverter issues alarm Er6.
Operation protection
Start check: To prevent a sudden start, the inverter prohibits any run operations and
displays Er6 if any run command is present when;
- The inverter power is turned ON,
- An alarm is released, or
- A run command source is switched via the communications link.
Er6
Tuning error
During tuning of motor parameters, if tuning has failed or aborted, or an abnormal
condition has been detected in the tuning result, the inverter stops its output.
Er7
RS-485
communications error
(port 1)
When the inverter is connected to a communications network via the RS-485 port designed
for the keypad, detecting a communications error stops the inverter output.
Er8
Data save error during
undervoltage
If the data could not be saved during activation of the undervoltage protection function, the
inverter displays the alarm code.
ErF
RS-485
communications error
(port 2)
When the inverter is connected to a communications network via the RS-485 port on the
control terminals DX+ and DX-, detecting a communications error stops the inverter
output.
ErP
Power supply LSI error
Detects an LSI failure on the power supply printed circuit board, which is mainly caused by
noise, and stops the inverter output.
ErH
Mock alarm
A mock alarm can be generated with keypad operations.
Err
Current input wire
break detection
If a break of the current input signal wire is detected, this function stops the inverter output
(Enable/Disable selectable).
CoF
PID feedback wire
break detection
When PID feedback is assigned to the current input, if a wire break is detected, this
function stops the inverter output. (Switchable between Enable and Disable)
PV1
PV2
PVA
PVb
PVC
Enable circuit failure
Diagnoses the Enable circuit. If any circuit failure is detected, this function stops the
inverter output.
ECF
Customizable logic
abnormality
Issues an alarm if a customizable logic configuration error is detected.
ECL
Dry pump protection
Displays an error if a dry pump condition is detected under PID control.
Pdr
Control of maximum
starts per hour
Displays an error if the slow flowrate stop function is frequently activated under PID
control.
roC
End of curve protection Displays an error if large volume of water condition is detected under PID control.
PoL
Anti-jam function
Displays an error if starting has failed due to overcurrent.
rLo
Filter clogging
prevention
Displays an error if overload is detected under PID control.
FoL
Protection
Password protection
Entering a wrong password five times causes an alarm.
LoK
Summary of Contents for FRENIC-AQUA series
Page 1: ...MEHT538b...
Page 2: ...User s Manual...
Page 13: ......
Page 15: ......
Page 33: ......
Page 35: ......
Page 61: ...2 26 Figure D Figure E NC No connection Do not make wiring NC NC...
Page 63: ...2 28 Figure J Figure K Charging lamp Charging lamp Viewed from A...
Page 83: ...2 48 Unit mm FRN45 to 55AQ1 4...
Page 84: ...2 9 External Dimensions 2 49 Chap 2 SPECIFICATIONS Unit mm FRN75 to 90AQ1 4...
Page 85: ...2 50 Unit mm FRN110AQ1S 4 FRN132AQ1S 4 FRN160AQ1S 4 FRN200AQ1S 4...
Page 87: ...2 52 Unit mm FRN500AQ1S 4 FRN630AQ1S 4 FRN710AQ1S 4...
Page 88: ...2 9 External Dimensions 2 53 Chap 2 SPECIFICATIONS 2 9 2 Keypad Unit mm Panel cutout...
Page 95: ......
Page 140: ...4 4 Options 4 33 Chap 4 SELECTING PERIPHERAL EQUIPMENT...
Page 279: ......
Page 281: ......
Page 341: ...6 60 Example of Thermal Overload Detection Characteristics...
Page 637: ......
Page 639: ......
Page 651: ...7 12 Figure 7 7 Terminal FM2 Output Selector...
Page 653: ......
Page 663: ......
Page 665: ......
Page 699: ......
Page 717: ......
Page 719: ......
Page 733: ......
Page 749: ......
Page 751: ...MEHT537 Phone 81 3 5435 7058 Fax 81 3 5435 7420 Printed in Japan 2012 08 H12b b12 CM00FOLS...