6.3 Details of Function Codes
6-109
Chap. 6
FUNCTION C
ODES
Explanations of each function are given in normal logic system "Active ON."
Function code data
Active
ON
Active OFF
Functions assigned
Symbol
Related
function
codes/signals
(data)
0 1000
Inverter
running
RUN
⎯
1
1001
Frequency (speed) arrival signal
FAR
E30
2
1002
Frequency (speed) detected
FDT
E31, E32
3 1003
Undervoltage detected (Inverter
stopped)
LV
⎯
5 1005
Inverter
output
limiting
IOL
⎯
6 1006
Auto-restarting after momentary power
failure
IPF
F14
7
1007
Motor overload early warning
OL
E34, F10, F12
10
1010
Inverter ready to run
RDY
⎯
11
⎯
Switch motor drive source between
commercial power and inverter output
(For MC on commercial line)
SW88
12
⎯
Switch motor drive source between
commercial power and inverter output
(For secondary side)
SW52-2
13
⎯
Switch motor drive source between
commercial power and inverter output
(For primary side)
SW52-1
E01 to E07
ISW50
(40)
ISW60
(41)
J22
15 1015
Select AX terminal function (For MC
on primary side)
AX
⎯
16
1016
Shifted to pattern operation stage
TU
17 1017
Pattern
operation cycle completed
TO
18
1018
Pattern operation stage number
STG1
19
1019
Pattern operation stage number
STG2
20
1020
Pattern operation stage number
STG4
C21 to C28
22
1022
Inverter output limiting with delay
IOL2
IOL
(5)
25
1025
Cooling fan in operation
FAN
H06
26 1026
Auto-resetting
TRY
H04, H05
27 1027
Universal
DO
U-DO
⎯
28 1028
Heat
sink
overheat early warning
OH
⎯
30 1030
Lifetime
alarm
LIFE
H42
33 1033
Reference
loss
detected
REF OFF
E65
35 1035
Inverter
output
on
RUN2
RUN
(0)
36 1036
Overload
prevention
control
OLP
H70
37 1037
Current
detected
ID
E34, E35
42 1042
PID
alarm
PID-ALM
J121 to J124
J221 to J225
43
1043
Under PID control
PID-CTL
J101, J201
44 1044
Motor stopped due to slow flowrate
under PID control
PID-STP
J149 to J160
J249 to J260
45
1045
Low output torque detected
U-TL
E80, E81
52 1052
Running
forward
FRUN
⎯
53 1053
Running
reverse
RRUN
⎯
54
1054
In remote operation
RMT
(See Section
5.5.4.)
Summary of Contents for FRENIC-AQUA series
Page 1: ...MEHT538b...
Page 2: ...User s Manual...
Page 13: ......
Page 15: ......
Page 33: ......
Page 35: ......
Page 61: ...2 26 Figure D Figure E NC No connection Do not make wiring NC NC...
Page 63: ...2 28 Figure J Figure K Charging lamp Charging lamp Viewed from A...
Page 83: ...2 48 Unit mm FRN45 to 55AQ1 4...
Page 84: ...2 9 External Dimensions 2 49 Chap 2 SPECIFICATIONS Unit mm FRN75 to 90AQ1 4...
Page 85: ...2 50 Unit mm FRN110AQ1S 4 FRN132AQ1S 4 FRN160AQ1S 4 FRN200AQ1S 4...
Page 87: ...2 52 Unit mm FRN500AQ1S 4 FRN630AQ1S 4 FRN710AQ1S 4...
Page 88: ...2 9 External Dimensions 2 53 Chap 2 SPECIFICATIONS 2 9 2 Keypad Unit mm Panel cutout...
Page 95: ......
Page 140: ...4 4 Options 4 33 Chap 4 SELECTING PERIPHERAL EQUIPMENT...
Page 279: ......
Page 281: ......
Page 341: ...6 60 Example of Thermal Overload Detection Characteristics...
Page 637: ......
Page 639: ......
Page 651: ...7 12 Figure 7 7 Terminal FM2 Output Selector...
Page 653: ......
Page 663: ......
Page 665: ......
Page 699: ......
Page 717: ......
Page 719: ......
Page 733: ......
Page 749: ......
Page 751: ...MEHT537 Phone 81 3 5435 7058 Fax 81 3 5435 7420 Printed in Japan 2012 08 H12b b12 CM00FOLS...