Farmer 400
Fav 700
Fav 900
Electrics / system in general
B031 / B032 - draft-sensing pin right / left
E
Testing
900 > 23/3001
16.2.2001
9000
000059
E
b
3/3
Capitel
Docu-No.
Index
Date
Version
Page
B031 / B032 - draft-sensing pin right / left
Text-module
Technical specifications of draft-sensing pins B031/B032
Text-module
Note:
Chapter 9000 Index E - Checking A005 - ECU, EPC
Chapter 8610 Index A - B031/B032 - functional description of draft-sensing pins
Supply voltage
9.5 VDC
Signal:
Tensile / compressive load
2.5 VDC / 7.5 VDC
Neutral
4.7 VDC
Rated load
Farmer 400
60 KN (6.0 t)
Fav. 700
90 KN (9.0 t)
Fav. 900
90 KN (9.0 t)
Overload limit
120 KN (12 t)