Farmer 400
Fav 700
Fav 900
Tractor / General system
Calibration code 7034
F
Setting and Calibration
05/2000
0000
000011
F
a
1/2
Capitel
Docu-No.
Index
Date
Version
Page
Calibration code 7034
Text-module
6. Calibrating the engagement point of the front PTO
Bullet-List
Caution: following preparatory steps must be carried out.
●
Handbrake on
●
Start engine
●
If error messages are displayed, faults must be individually cleared
Text-module
Text-module
First press key and hold,
then press key, and fault symbol is cleared. Clear other faults in same way.
Press key, next pictogram displayed.
Key flashes
Press key three times , next pictogram displayed
Key flashes
Press key, next pictogram displayed
Input code 7034
Press one of keys until desired number is displayed.
Store with key, following pictogram displayed