Operation and function of shock load damping system
Text-module
When is shock load damping actuated?
Shock load damping is actuated if the following criteria are met:
Text-module
The EPC must be unlocked (open lock in Vario terminal or operate rapid lift control on control
console).
Text-module
The rapid lift control on the control console must be in the transport position ("Raise" position).
Text-module
The tractor must be driving faster than the shock load damping actuation speed (setting on Vario
terminal A008).
If the shock load damping actuation speed is exceeded, the lift assembly lowers by approx. 3% to the
mean oscillation axis.
If the speed is 25% less than the shock load damping actuation speed, the lift assembly is raised by
approx. 3%.
Text-module
Adjusting the actuation speed for shock load damping
PM-Picturemodule
PM-Picturemodule
Text-module
PMTAB_Picture
Press F5 and this submenu is displayed.
PMTAB_Picture
Use rotary control (P2) to set display (B) to
desired actuation speed.
Adjustment range 0 - 30 km/h
A
= Calibration of radar sensor A011 (see
tractor operating manual)
C
= Setpoint wheel slip for slip control of rear
power lift (see tractor operating manual)