Electric / System in General
B006 -Intake Air Temperature Sensor
E
Testing
900 > 23/3001
24.11.2000
9000
000042
E
a
2/2
Capitel
Docu-No.
Index
Date
Version
Page
B006 -Intake Air Temperature Sensor
Checking Warning Display with resistor decade
Component B006 separately
Connect Adaptor Connectro X 899.980.251.102 onto connector X155.
Connect resistor decade X 899.980.224 and select desired Value.
Ignition "ON".
Continuous Beep and Warning is displayed on dashpanel A007 .
Measuring Point on Dashpanel A007
Pin
Earth
15 and 18
Signal
26