Fav 700
Fav 900
Hydraulics / Valve fitting
Removing and fitting control pressure microfilter - FF
G
Repair
Fav 900 chassis number 23/3001 and up
25.07.2001
9620
000003
G
a
6/7
Capitel
Docu-No.
Index
Date
Version
Page
Removing and fitting control pressure microfilter - FF
PM-Picturemodule
PM-Picturemodule
PM-Picturemodule
PM-Picturemodule
PMTAB_Picture
Insert microfilter - FF.
PMTAB_Picture
Fit new O-rings to drain plug.
PMTAB_Picture
Tighten drain plug to 125 +40 Nm.
PMTAB_Picture
Fav 700
End plate with external heater circuit
(hydraulic oil preheater)
Tighten drain plug of measuring point M5 to
20 +5 Nm .