![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_4001870983.webp)
Farmer 400
Fav 700
Fav 900
Electronics / system in general
B009 - output temperature sensor
E
Testing
711 / 712 > 21/1001 – 714 / 716 > 21/2001; 900 > 23/...;
02/2000
9000
000017
E
a
1/1
Capitel
Docu-No.
Index
Date
Version
Page
B009 - output temperature sensor
Single e-box
Text-module
Note:
Connect adapter cable X 899.980.251.102 to connector X158.
Component B009 remains isolated.
Ignition "ON".
Connect resistor decade X 899.980.224 and select desired value.
Warning must be displayed on instrument panel. Fault code is stored.
PM-Picturemodule
Text-module
Pin
Function
1
Signal
2
Earth
Temperature
in
Resistance
Fault code
°
C
Ohm
50
150
60
105
95
40
105
35
110
30
4.1.53
PMTAB_Picture
Note:
Warning message is displayed on instrument
panel from 95
°
C upwards in range II. Warning
message is always displayed at 105
°
C and
above. In addition, fault code 4.1.53 is stored at
110
°
C and above.
Measuring points on A004 - control
console
Pin
Earth
1
Signal
21