![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_40018701017.webp)
Farmer 400
Fav 700
Fav 900
Electrics / system in general
G001 - battery
E
Testing
21.2.2001
9000
000081
E
a
1/1
Capitel
Docu-No.
Index
Date
Version
Page
G001 - battery
PM-Picturemodule
PM-Picturemodule
PM-Picturemodule
PMTAB_Picture
G001 = battery
Check battery charge with aid of open-circuit
voltage.
Test conditions: ambient temperature approx.
27
°
C
PMTAB_Picture
For six hours before test do not charge battery or
connect to consumer. Disconnect earth cable
from battery.
Connect multimeter (voltmeter).
Target values at 27
°
C:
12.8 VDC = full
12.1 VDC to 12.25 VDC = 1/2
11.4 VDC to 11.8 VDC = empty
PMTAB_Picture
Complaint: battery goes flat without any
consumers being switched on.
Check discharge current using multimeter
(ammeter).
Switch off all consumers. Disconnect battery's
earth cable, and connect multimeter (ammeter) in
series.
Consumption must not exceed 50 mA.