Farmer 400
Fav 700
Fav 900
Power lift / Electrohydraulic control EPC
Slip control performance test
E
Testing
Fav 900 chassis number 23/3001 and up
07.05.0001
8610
000003
E
a
2/6
Capitel
Docu-No.
Index
Date
Version
Page
Slip control performance test
- Calibrating speed display
PM-Picturemodule
Text-module
Note:
During the calibration process the tractor may only be driven using the clutch pedal.
If the joystick A003 is used, the ACTIVE pictogram which is displayed deletes the calibration
process menu when the tractor stops at the gauge points.
Bullet-List
●
Accurately measure and mark out gauge length of between 30 m (minimum) and 100 m (maximum).
Text-module
Distance must now be set to length of measured distance, e.g. 50 m.
Once last digit has been confirmed, "START" flashes.
Bullet-List
●
Position tractor front wheel precisely on start mark.
PM-Picturemodule
Text-module
Bullet-List
PMTAB_Picture
Press key (BI) to display function selection.
Press one key repeatedly until "Calibrating speed display" pictogram (F) flashes.
Press key, screen as shown (J) appears, 1st digit of distance flashes.
Press one key repeatedly until desired figure is displayed, e.g. 0..
Press key. Set remaining two digits as per 1st digit, e.g. 050.
PMTAB_Picture
Press key, display changes from "START" to "STOP".