If figures do not appear when you actuate relevant potentiometer, there is a fault.
Press ESC key to exit blue screen, and Fendt start page is then displayed.
or
Switch ignition off and on to exit blue screen, and Fendt start page is then displayed.
PMTAB_Picture
If settings can no longer be changed via
potentiometers P1 - P3, proceed as follows:
1. Switch off tractor ignition
2. Hold down keys F1, F3 and F5 on terminal at
same time as turning ignition on.
3. Instead of Fendt start page, blue screen is
now displayed containing following data.
PMTAB_Picture
"Encoder 1" to "Encoder 3" shows current status
and numerical values of three potentiometers. If
you turn relevant potentiometer, 4-digit figure
counts pulses up or down hexadecimally.
If you turn potentiometer slowly, following
sequence should be observed:
00 -> 01 -> 11 -> 10 -> 00 etc.
If you turn in opposite direction, then sequence
read correspondingly from left to right is