Electrics / system in general
A004 - control console
E
Testing
711 / 712 > 21/1001 - 714 / 716 > 21/2001; 900 > 23/3001;
6.3.2001
9000
000092
E
a
3/4
Capitel
Docu-No.
Index
Date
Version
Page
A004 - control console
Single e-box
Text-module
Text-module
Pin
Pin description
Signal type
Signal at component
Signal from
A004 (break
in cable)
21
B009 output temperature sensor
Digital input
For figures see Chapter
9000 Index E (B009)
8.0 V
22
S017 clogged filter pressure-opera-
ted switch
Digital input
System OK 2.4 V
8.0 V
Pressure filter clogged
5.1 V
23
A013 fuse board ABC
8.5 V output for
sensors
8.5 V
8.5 V
24
Not assigned
25
Not assigned
26
CAN-low
- wire
approx. 2.9 V
27
CAN-high
+ wire
approx. 1.7 V
28
A004 control console electronics On
/ Off +15
D+ input
12 V
0 V
29
A003 joystick, hand throttle memory
keys only on Fav 900/23/3001
(EDC)
For values see chapter
2710 section A speed
adjustment EDC
30
B035 hand throttle angular resolver
only on Fav 900/23/3001 (EDC)
For values see chapter
2710 section A speed
adjustment EDC
Pin
Pin description
Signal type
Signal at component
Signal from
A004 (break
in cable)
31
Not assigned
32
B003 suspension angular resolver
Current input
Upper limit position:
8.2 mA
Lower limit position:
18 mA
Upper limit position:
1.6 V
Lower limit position:
3.6 V
33
Not assigned
34
S047 exhaust brake plunger-opera-
ted switch
Digital input
Switch not actuated
2.4 V
8.0 V
Switch actuated 5.1 V
35
S045 reversing system solenoid
switch)
Digital input
Forwards 5.1 V
8.0 V
Reverse 2.4 V
36
Not assigned
37
Not assigned
38
Not assigned
39
S034 coolant level switch
Digital input
Level OK: 2.4 V
8.0 V
too low 5.1 V
40
S022 external switch, lower front
power lift
Digital input
Rest position 5.1 V
8.0 V
Lower 2.4 V