Tractor / General system
Calibration code 4007
F
Setting and Calibration
12/1999
0000
000008
F
a
3/5
Capitel
Docu-No.
Index
Date
Version
Page
Calibration code 4007
Check:
Text-module
If incorrect values are found or conditions are not met, ERROR message is displayed.
If calibration proceeds without errors, OK is displayed, and new sensor settings are stored.
Text-module
Note:
Data are only accepted when ignition key is turned to position "0".
Text-module
Press key and hold,
then press key
Possible error messages when calibrating the transmission ratio, code 4007
Error message
Cause / remedy
F 1
Preconditions not met
F 2
1. After ignition OFF relay in transmission e-box has not released. Once ignition
has been switched off, release of relay in transmission e-box must be audible.
2. Test plug connections to actuator unit.
F 3
Actuator unit does not go to exact setpoint. Test ease of movement of
transmission control, e.g. engage emergency control and test.
F 4
Transmission ratio has not been adjusted within 8 sec. Test ease of movement of
transmission control, e.g. engage emergency control and test.
F 5
Step 1 = actuator unit does not find zero point from 0 in forward direction.
Step 2 = actuator unit does not find zero point from 0 in reverse direction.
Test connection between actuator unit and actuator shaft.
F 6
See error message F 5
F 7
Step 2: zero points of transmission control unit for forward and reverse travel are
too far apart, greater than 8
°
.
Test connection between actuator unit and actuator shaft. Actuator unit.
F 8
Step 3: maximum point of transmission ratio forwards not found. Target value
min. 155
°
, max. 187
°
.
Step 4: maximum point of transmission ratio in reverse not found. Target value
min. 136
°
, max. 165
°
.
Test connection between actuator unit and actuator shaft.
F 9
Step 3: actuator shaft is displaced by more than 155
°
forwards. However,
transmission displacement reacts by less than 155
°
.
Step 4: actuator shaft is displaced by more than 135
°
forwards. However,
transmission displacement reacts by less than 135
°
.
Test connection between actuator unit and actuator shaft. Actuator unit.
F 10
Transmission ratio characteristic curve not logical. For example, forward set,
reverse detected. Repeat calibration. See also error message F 2 Test rotational
direction signal from accumulator shaft sensor.
F 11 / F 12
Step 7 = verify figures of steps 1 to 6. ML transmission ratio not OK. Repeat
calibration. See also error message F 2 Then, if necessary, test hydrostatic
power branch, e.g. by means of Emergency mode.
F 13
1. Incorrect EOL programming (before step 1)
2. Stored values in transmission e-box not logical
Remedy:
1. Run EOL programming again
2. See 1, if necessary fit new transmission e-box.
F 14
See F 11 / F 12