Farmer 400
Fav 700
Fav 900
Electrics / General system
S047 - switch, exhaust brake
E
Testing
711/712 >21/1001- 714/716>21/2001; 900>23/3001
31.07.2001
9000
000136
E
a
1/2
Capitel
Docu-No.
Index
Date
Version
Page
S047 - switch, exhaust brake
Single ECU
PM-Picturemodule
Text-module
Text-module
Pin
Function
1
Earth
2
Signal
PMTAB_Picture
Connect e-adapter box X 899.980.208.100
directly to A004 - ECU.
Measuring points on A004 - ECU, control con-
sole
Pin
Earth
1
Signal
34
Test
Pin
Target
value
Condition
Possible cause of fault
Resistance
2
121 ohms S047 - switch not
actuated
510 ohms S047 - switch actuated
1