![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_40018701029.webp)
Farmer 400
Fav 700
Fav 900
Electrics / system in general
M009 - fan
E
Testing
21.02.2001
9000
000073
E
a
2/2
Capitel
Docu-No.
Index
Date
Version
Page
M009 - fan
PM-Picturemodule
PM-Picturemodule
PM-Picturemodule
Text-module
Note:
Electric circuit diagrams - Chapter 9000 Index C
PMTAB_Picture
Mark and disconnect electrical leads.
1
= orange
2
= yellow
3
= green
4
= red
PMTAB_Picture
Checking overheating fuse
Behr can supply resistor with overheating fuse as
spare part.
In event of complaint thatpower supply is OK, but
fan motor will not run:
Test with multimeter (ohmmeter):
Target value: resistance of overheating fuse
approx. 0 ohm.
PMTAB_Picture
Checking resistances
Target value for overall resistance: approx. 2
ohms
This total resistance is made up of 1.6 + 0.4 ohms.