Fav 900
Engine / Systems
Trouble shooting program EDC
B
Faults
Fav 900 chassis number 23/3001 and up
16.11.2000
2000
000001
B
b
43/72
Capitel
Docu-No.
Index
Date
Version
Page
Trouble shooting program EDC
Pump Control Module (Fuel temperature.) A020 (Test 27)
Failure Code (Fendt):
1.2.42
Text-module
Failure location (MAN):
42
Text-module
Failure display:
Message on Dashpanel
Text-module
Failure path:
Injection Pump (Control Module) Fuel Temperature to high or Temperature sensor failure.
Text-module
Consequences:
If values are not plausible, system will switch to substitution Value (75
°
C) . Fuel Flow will be reduced
according to Speed.
Text-module
Possible Origin:
Fuel Temperature to high , Injection Pump Failure
Text-module
Remark:
Before Replacing any Pump or Control Module, failure Codes must l be analyzed and then deleted.
In case of several Failure Codes, check first the Test procedures wich are not requesting a replacement
of the Control Module or of the pump.
Text-module
Remark 2:
Fuel Temperature Sensor is an integrated part of the injection Pump and cannot be replaced
separately.
Text-module
Text-module
Test
Measurement
Trouble shooting
Injection Pump
Failure thresholds : t >130
°
C or < -45
°
C
will be substituted by 20
°
C.
- Record Failure and ambient Para-
meters with FENDIAS
Check with FENDIAS wether Values are
out of thresholds but realistic (e.g. Tem-
peratur by cold Engine).
- Delete Failure Code Memory with
FENDIAS
- Check again with FENDIAS, let fuel
cool down
- If Failure Persists, Replace Injection
Pump