![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_4001870519.webp)
Fav 900
Engine / Systems
Trouble shooting program EDC
B
Faults
Fav 900 chassis number 23/3001 and up
16.11.2000
2000
000001
B
b
14/72
Capitel
Docu-No.
Index
Date
Version
Page
Trouble shooting program EDC
High Pressure Solenoid Valve (Q-MV) in Injection Pump (Plausibility Supply
time)
(Test 2)
Failure Code (Fendt):
1.2.82
Text-module
Failure location (MAN):
82
Text-module
Failure display:
Message on Dashpanel
Text-module
Failure path:
Duration of supply of Solenoid Valve , Flow signal wich is communicated via CAN-Bus to Pump
Text-module
Consequences:
Engine will be stopped
Engine does not start
Text-module
Possible Origin:
Injection Pump Failure, Supply / Earth VP44 not OK
Text-module
Text-module
Test
Measurement
Trouble shooting
Injection Pump
Check Voltage supply/ Earth VP44, Pin
6,7, A020 ,Connector X046 by putting
load on Supply wires WM1041, WM1352
- Record Failure and ambient Para-
meters with FENDIAS
- Delete failure Memory using FEN-
DIAS
- Check again with FENDIAS
- Check Connectors
- If Failures are still persisting , re-
place Injection Pump