![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_4001870798.webp)
Farmer 400
Fav 700
Fav 900
Power lift / Electrohydraulic control EPC
Operation and function of electronic slip control
A
General
Fav 900 chassis number 23/3001 and up
11.04.2001
8610
000006
A
a
2/5
Capitel
Docu-No.
Index
Date
Version
Page
Operation and function of electronic slip control
Electronic slip control settings
PM-Picturemodule
PM-Picturemodule
PM-Picturemodule
PMTAB_Picture
Switching electronic slip control on and off
Call up rear power lift submenu.
PMTAB_Picture
A
= Electronic slip control is switched on and
off by pressing F2.
Slip control remains activated as long as tractor is
moving. If it is stationary for longer than 30 sec,
slip control switches off automatically.
Press F2 again to reactivate slip control.
Slip control does not operate in floating position or
position control mode.
PMTAB_Picture
Setting wheel slip
C
= Use rotary control P3 to set display
showing percentage wheel slip at which
lift assembly is raised. Setting range
from 3% to 60% wheel slip
A
= Gauge length for radar sensor calibration
B
= Shock load damping actuation speed (see
Chapter 8610 Reg.A - Operation and
function of shock load damping)