Farmer 400
Fav 700
Fav 900
Power lift / Electrohydraulic control EPC
Operation and control conditions of EPC-C
A
General
Fav 900 chassis number 23/3001 and up
11.04.2001
8610
000003
A
a
3/5
Capitel
Docu-No.
Index
Date
Version
Page
Operation and control conditions of EPC-C
PM-Picturemodule
PM-Picturemodule
PMTAB_Picture
Operation at control console A004
G
= Setpoint / depth control (item 10 on
setting scale = floating position)
H
= Rapid lift control with transport lock
"Stop" mid-position = Electronic systems
disabled (no correction)
End "Raise" position (H2) = Transport position
with shock load damping for mounted
implement
Go "Control" position (H1) = Lower or
implement is moved to setpoint depth.
Rapid lowering system, power lift
moves to floating position and then
regulates to setpoint depth (e.g.
plough at headland)
Hitch lift, locking of hitch
Rear power lift "Automatic" pressed,
rapid lift control toggle switch is
transferred to rear EPC rocker
switch on joystick.
PMTAB_Picture
Operation at joystick A003
A1 / A2 = Front enhanced power lift switch
(position control) (optional extra)
B1
= Go "Control" position = lower or
implement is moved to setpoint depth.
B2
= End "Raise" position = raise rear power lift
(as far as lift height limit "stop")
D
= Activating control must be pressed when
actuating rocker switch (B1 and B2) and
switches A1 and A2 (front enhanced
power lift, optional extra).
C
= Stop key, lift assembly (front / rear)
remains in current position.
(Emergency OFF)