Fav 900
Engine / Systems
Trouble shooting program EDC
B
Faults
Fav 900 chassis number 23/3001 and up
16.11.2000
2000
000001
B
b
68/72
Capitel
Docu-No.
Index
Date
Version
Page
Trouble shooting program EDC
Failure during CAN - Message Transmissiont (Test 50)
Failure Code (Fendt):
1.2.E0
Text-module
Failure location (MAN):
E0
Text-module
Failure display:
Message on Dashpanel
Text-module
Failure path:
EDC Control Module (A021)
Text-module
Consequences:
None
Text-module
Possible Origin:
CAN from EDC Control UModule are not connected
Text-module
Test condition:
Adaptor box with adapting connectors connected
Text-module
Use wiring diagrams wich are corresponding to the tractor
Text-module
Test
Measurement
Trouble shooting
CAN-Bus EDC Control
Module to EST Control
Module
Check Voltage with adaptor box with ad-
aptor Connectors between Pin B3/B4
and Pin B1/B2 on Control Module A021,
Connector X048 (
- Record Failure and ambient Para-
meters with FENDIAS
- Delete Failure Code Memory with
FENDIAS
Requested value : U Bat while Ignition
is "OFF", As long Relay Time Delay oc-
curs within EST Control Module. Battery
main switch will be held from EDC Con-
trol Module (Hold Circuit)
- Check again with diagnostic pro-
gram
Failure Condition: Relay must come
into Rest Position within 5 Seconds.
- Check Wires
- Check Connectors