![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_40018701050.webp)
Farmer 400
Fav 700
Fav 900
Electrics / system in general
Pressure-operated switch S025 and flow monitor S026
E
Testing
6.3.2001
9000
000091
E
a
4/9
Capitel
Docu-No.
Index
Date
Version
Page
Pressure-operated switch S025 and flow monitor S026
Text-module
*)
Text-module
Text-module
2nd operating scenario: "Malfunctions"
Outline circuit diagram with measuring points
PM-Picturemodule
Text-module
Bullet-List
Notes on electrical measurements:
●
Voltage measurements (volts): between measurement pin and analogue, digital or vehicle earth
●
Current measurements (mA): using 68-pin adapter box between green and yellow measurement
pins
●
Test values at e-box and at 31-pin cable coupler X006 are identical
Text-module
9.5
mADC
Pressure-opera-
ted switch
X235
1
5.1
VDC
Flow monitor
X236
1
5.1
VDC
Modification
Validity
E-box
Interface
Measure-
ment pin
Twin-box version
FAV700 up to chassis
no. < 2000
A002
X031
44
Single-box version
A004
X033
45
PMTAB_Picture
Tractor
Component condition
Measuring point
Test value
condition
Hydraulics condition
Fault code