8.3.32
B032
Rear EPC left
draft-sensing pin
Signal line fault
Restricted control quality
with traction control
"Electrohydraulic power
lift control" circuit
diagram
REAR EPC
DRAFT-SENSING PIN
Fault in 9,5 V supply to
A005
Sensor fault
8.3.33
G001;
G002
Battery 1; battery 2
Battery voltage
< 11 volts
"Power Ub"
circuit diagram
8.3.34
Rear power lift
"Lowering speed" rotary
control
Signal fault
Cannot be changed
"Electrohydraulic power
lift control" circuit
diagram
Only for FAV900 with
twin control modules
8.3.35
Rear power lift
"Operating mode" rotary
control
Signal fault
Cannot be changed
"Electrohydraulic power
lift control" circuit
diagram
Only for FAV900 with
twin control modules
8.3.38
Rear power lift pressure
sensor
Signal fault, pressure
sensor fault
Control is continued
"Electrohydraulic power
lift control" circuit
diagram
Only for FAV900 with
twin control modules
8.3.39
Rear power lift "Rapid
lowering / Hitchlift"
switch
Signal fault
Control is continued
"Electrohydraulic power
lift control" circuit
diagram
Only for FAV900 with
twin control modules
8.3.40
(A004) Rear power lift rapid lift
control
Fault in switch / A004
contact
Lifting and lowering only
via external controls
"Electrohydraulic power
lift control" circuit
diagram
REAR EPC
ACKNOWLEDGEMEN-
TS / STATUS
CAN (K-Bus) fault A004
/ A005
8.3.41
(A004) Rear power lift rapid lift
control
Fault in switch / A004
contact
Rapid lowering system
not functioning
"Electrohydraulic power
lift control" circuit
diagram
REAR EPC
ACKNOWLEDGEMEN-
TS / STATUS
CAN (K-Bus) fault A004
/ A005