![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_4001870556.webp)
Fav 900
Engine / Systems
Trouble shooting program EDC
B
Faults
Fav 900 chassis number 23/3001 and up
16.11.2000
2000
000001
B
b
51/72
Capitel
Docu-No.
Index
Date
Version
Page
Trouble shooting program EDC
Solenoid Valve Final Stage (Pump Conmtrol Module Autodiagnostic) A020
(Test 35)
Failure Code (Fendt):
1.2.C9
Text-module
Failure location (MAN):
C9
Text-module
Failure display :
Message on Dashpanel
Text-module
Failure path:
Hardware Failure within Final Stage Solenoid Valve (Pump Control Module)
Text-module
Consequences:
none known
Text-module
Function:
Check final stage in PSG - Autodiagnostic
Text-module
Possible Origin:
Pump Control Module Failure
Text-module
Remark 1:
Before Replacing any Pump or Control Module, failure Codes must l be analyzed and then deleted.
In case of several Failure Codes, check first the Test procedures wich are not requesting a replacement
of the Control Module or of the pump.
Text-module
Text-module
Test
Measurement
Trouble shooting
Injection Pump
Failure Conditions: no Indications avai-
lable
- Record Failure and ambient Para-
meters with FENDIAS
- Delete Failure Code Memory with
FENDIAS
- Check again with FENDIAS
- If failure persists, Replace Injection
Pump