Hydraulics / General system
Hydraulics comparison of Fav 700 with Fav 500, 800, 900 and XYLON
A
General
12/1999
9600
000003
A
a
2/3
Capitel
Docu-No.
Index
Date
Version
Page
Hydraulics comparison of Fav 700 with Fav 500, 800, 900 and XYLON
Switchover
Spool valves, key on control console
From 6/99: externally enclosed
Externally enclosed
Mechanical block ball valve
Mechanical block ball valve
Possible option
-
Pressure sensor (regulator) for front
and rear power lift
Shuttle valves
Principle, operation, required quantity
- position
Integrated in central control block
Externally enclosed in part
Maintenance
(acc. to op. hours)
Return flow filter
change
Initially after 500, then every 1000
Control pressure
microfilter
Initially after 500, (see Maintenance
Schedule)
(Not available)
Oil change
Initially after 1000, then every 1000
High-pressure filter in
flow monitor
Maintenance-free
Oil grade as per Maintenance Schedule
Commissioning specification (LS pump)
Measuring and
testing of existing
pressure-measuring
points
M1 (not required and therefore not
available)
M1 = LS pump (depending on
accessibility)
M2 = auxiliary pump
M2 = auxiliary pump
M3 = LS pump
M3 = LS pump
M4 = LS pressure (marked at central
control block)
M5 = 22 bar control pressure (at end
plate)
Abridged version and hydraulics comparison (Forts.)
FAVORIT 700
FAV 900, 800, 500, XYLON