![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_4001870838.webp)
Farmer 400
Fav 700
Fav 900
Power lift / Electrohydraulic control EPC
Slip control performance test
E
Testing
Fav 900 chassis number 23/3001 and up
07.05.0001
8610
000003
E
a
5/6
Capitel
Docu-No.
Index
Date
Version
Page
Slip control performance test
Control loop of slip control
PM-Picturemodule
Text-module
Text-module
The bevel pinion speed sensor B015 transmits the "theoretical speed" (A) to the ECU A002.
The radar sensor A011 transmits the "actual speed" (B) to the EPC ECU A005 and to the instrument
panel A007.
Text-module
The ECU A002 is connected to the EPC ECU A005 and the instrument panel A007 via the K-bus.
The "theoretical speed" (A) is transmitted to the EPC ECU A005 and the instrument panel A007 via the
K-bus.
Text-module
EPC ECU A005 ---> slip control (see also: Chapter 8610 Reg.A - Operation and function of electronic
slip control)
Instrument panel A007 ---> speed and slip display
Note:
Above 15 km/h the system automatically switches to theoretical speed display. The slip and
speed display are cleared. Below 15 km/h the actual speed is displayed again on the instrument
panel A007.
The slip control in the EPC ECU A005 remains active irrespective of the speed.
Implement socket X007 ---> implement control system (e.g. spraying computer)
Text-module
PMTAB_Picture
Item
Designation
Item
Designation
A002
ECU
X007
Implement socket
A005
EPC ECU
X100
Instrument panel plug (blue)
A007
Instrument panel
X101
Instrument panel plug (yellow)
A011
Radar sensor
A
"Theoretical speed" signal
B015
Bevel pinion speed sensor
B
"Actual speed" signal