Troubleshooting table for M011 - starter, 24 V starter motor
B
Faults
07.08.2001
9060
000001
B
a
3/3
Capitel
Docu-No.
Index
Date
Version
Page
Troubleshooting table for M011 - starter, 24 V starter motor
Text-module
Note:
Chapter 9000 Reg. E - Measuring and testing electrical components
PM-Picturemodule
M011 - starter runs on after S002 - switch has been released
Cause
Remedy
S012 - switch does not switch off or starter relay or
K008 - relay or K018 - relay does not disconnect
Switch engine off immediately, check relay
Fault: pinion does not disengage once engine starts
Cause
Remedy
Return spring stretched or broken
Have M011 - starter repaired in specialist work-
shop.
Caution:
If M011 - starter is removed, disconnect earth cables from G001 and G003 - batteries.
PMTAB_Picture
●
Using jump leads, connect external start
te (X419) to positive terminal of battery
which is delivering power (12 - 14 VDC).
●
First connect jump lead to negative terminal of
battery providing power (12 - 14 VDC), then to
external start terminal (X418).