![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_4001870233.webp)
Fav 900
Transmission / Transmision Control
Transmission Pressures Recordings
E
Testing
Fav 900 ab 23 / 3001
04.12.2000
1005
000002
E
2/4
Capitel
Docu-No.
Index
Date
Version
Page
Transmission Pressures Recordings
Text-module
II. High Pressure measurement
Preliminaries: Operating range II, Acceleration ramp 4 or
Auxilliary operation ( By turning the handle do not exceed an angle of 15
°
risk of Oil overheating!
Text-module
Text-module
NOTE:
Hochdruckkreis PH maximal 5 Sekunden belasten und dabei nachfolgende Messungen
durchführen.
Text-module
III. Checking control pressures
Supply alternately 12 V
DC
to Solenoid valve 1 (4V1) and 2 (4V2)
Text-module
Text-module
DANGER:
High Pressure measurement must not exceed 5 Seconds for Reverse and Forward,
risk of Oil overheating!
Meßstelle
Motordrehzahl
Sollwert in bar
Istwert in bar
PH
1600
Neu 500 + 20
Längere Zeit im Einsatz
500 - 40
Measuring Point
Engine speed
Requested value in bar
Actual value in bar
P
1600
26 ± 2
ES
1600
13 ± 2
AS
1600
12 ± 2
SM
1600
1,6 ± 0,4
Measuring Point
Engine speed
Requested value in bar
Actual value in bar
I and II
1600
26 ± 2
Operating range swit-
ching 1 + 2