![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_40018701154.webp)
Fav 700
Fav 900
Hydraulics / Valve fitting
Nitrogen diaphragm accumulator - STSP
E
Testing
Fav 900 chassis number 23/3001 and up
04.12.2001
9620
000002
E
a
4/5
Capitel
Docu-No.
Index
Date
Version
Page
Nitrogen diaphragm accumulator - STSP
PM-Picturemodule
Text-module
Fav 711/712 /21/ chassis number 1001 and up; 714/716 /21/ chassis number 2001 and up
Fav 900 /23/ chassis number 3001 and up
Text-module
Fav 714/716 /21/ chassis number up to 2000 (Y032 - control pressure solenoid valve is actuated
via K011 - relay)
Text-module
Bullet-List
●
Connect e-adapter box X 899.980.208.100 directly to A002 ECU, enhanced controls.
●
Isolate toggle switch pin 56 at e-adapter box.
●
Isolate toggle switch pin 52 at e-adapter box.
●
Provide external power source for Y032 - control pressure solenoid valve.
Drawing of external power source for Y032 - control pressure solenoid valve
PMTAB_Picture